HEATING TECHNIQUE
Wood pellet firing boilers EKO-CKS P UNIT (140–560 kW)
EKO-CKS P UNIT hot water central heating boiler is designed for burning wood pellets. It consists of EKO-CKS P boiler body in welded steel design and equipment for combustion of wood pellets: Cm Pelet-set 200-600 kW. It is necessary to upgrade the EKO-CKS P UNIT boiler with a pellet tank (e.g. CentroPelet box), and EKO-CKS P UNIT 560 boiler’s standard delivery includes cyclone and fan. Standard version is equipped with a pellet burner prearranged for automatic air-clean- ing of the grate while the boiler can be additionally equipped auto- matic ash removal set and air-cleaning of flue passages in the boiler. Digital control manages the operations of the burner (boiler), pellet transporter and additional equipment and all mentioned parts com- pose a functional unit.

Wood pellet firing boilers EKO-CKS P UNIT (140–560 kW)

PRODUCT CHARACTERISTICS

SUITABLE FOR THE ENVIRONMENT

Low emission of harmful compounds in the flue gases.

TOUCH SCREEN

Multifunctional digital control with colour touch screen display.

EXTENSIONS

Additional equipment: air-cleaning of flue passages, ash removal, cyclone with fan, CM2K, CM-GSM, PC, tablet or mobile phone monitoring.

AUTOMATIC CLEANING

Pellet burner prearranged for automatic air- cleaning of the grate.
 Wood pellet firing boilers EKO-CKS P UNIT PRODUCT CHARACTERISTICS Wood pellet firing boilers EKO-CKS P UNIT PRODUCT CHARACTERISTICS
Class 5 boiler. Steel hot water boilers with a pellet burner with nominal heat output: 140, 180, 230, 280, 320, 430, 499, 560 kW Boiler must be connected to accumulation tank (min. 10 l/kW) or hydraulic separator. Multifunctional digital control with colour touch screen display. Additional equipment: air-cleaning of flue passages, ash removal, cyclone with fan, CM2K, CAL, CM-GSM, system for monitoring the boiler operation via PC, tablet or mobile phone. They are meant to be installed in open or closed heating systems. It is possible to order a boiler with a lambda probe, EKO-CKS P-L Unit. The boiler is manufactured in accordance with the standards EN 303-5:2012 as well as ISO 9001 and ISO 14001.

BASIC DIMENSIONS:

3
1 2 EKO-CKS P Unit 140/180 EKO-CKS P Unit 140-430 - with cyclone and fan (additional equipment) EKO-CKS P Unit 499-560 - with cyclone and fan (standard delivery)
EKO-CKS P Unit 230-430
EKO-CKS P Unit 140-320 - expansion vessel 50 lit. - 1 kom, electromagnetic valve - 1 kom, air supply pipe - 1 kom EKO-CKS P Unit 430-560 - expansion vessel 23 lit. - 2 kom, electromagnetic valve - 2 kom, air supply pipe - 2 kom
4
4
3
2
1
11
8
7
6
5
1 2 1 3 14
Boiler EKO-CKS P 140-560 Burner CPPL 200-600 Electrical distribution box Control unit Pellet transporter CPPT 200-600 Expansion vessel
Compressor Electromagnetic valve Air feeding tube Air feeding tube 1 Pellet tank
Automatic ash removal (additional equipment) Cyclone CCP Fan 15 Flue gas chamber / flue gas chamber C/V (for cyclone and fan)
9 10
4 4 4 4 4
3 3
3
3a
Automatic boiler cleaning (additional equipment)
EKO-CKS P UNIT
140
Depth (A) Height(B) Width (C) Depth (D) Visina (E) Connections inlet/outlet
(mm) (mm) (mm) (mm) (mm) (R)/DN
180 230 280 320 430 560
2620 2105 3300 3265 2210 2"
1 3 3
3020 2105 3300 3650 2210 2"
1 3 3
3020 2105 3300 3650 2210 DN80
2 3 3
3330 2300 3345 3985 2580 DN80
2 3 3
3330 2400 3420 4160 2725 DN80
2 3 3
4225 2565 3900 4690 2895 DN100
2 3 3
- - 360 0 4775 520 0 5200 287 0 3230 DN100
499 - -
DN100

BASIC DELIVERY:

Boiler
Output range (kW)
EKO-CKS P 500
129 - 430
EKO-CKS P 380
96 - 320
EKO-CKS P 250
69 - 230
EKO-CKS P 300
84 - 280
- pellet tank - boiler outlet protection with a motor operated 3-way mixing valve and boiler pump - accumulation tank (min 10 l/kW) or hydraulic crossover
EKO-CKS P 150
42 - 140
EKO-CKS P 200
54 - 180
Cm Pelet-set 200: - pellet burner CPPL-200 inv (with automatic cleaning) - expansion vessel 50 lit. - compressor
-
boiler control - pellet screw conveyor CPPT-200 - electromagnetic valve - air feeding tube
Cm Pelet-set 300: - pellet burner CPPL-300 inv (with automatic cleaning) - expansion vessel 50 lit. - air compressor
- boiler control - pellet screw conveyor CPPT-300/350 - electromagnetic valve - air feeding tube
Cm Pelet-set 350: - pellet burner CPPL-350 inv (with automatic cleaning) - expansion vessel 50 lit. - air compressor
- boiler control - pellet screw conveyor CPPT-300/350 - electromagnetic valve - air feeding tube
Cm Pelet-set
Obligatory additional equipment
Additional equipment
Basic delivery
EKO-CKS P UNIT 430
EKO-CKS P UNIT 320
EKO-CKS P UNIT 280
EKO-CKS P UNIT 230
EKO-CKS P UNIT 180
EKO-CKS P UNIT 140
Cm Pelet-set 600: - pelet burner CPPL-600 inv (with automatic cleaning) - 2 pcs of expan. vessel 23 lit. - air compressor - boiler control
- pellet screw conveyor CPPT-600 - 2 pcs of electromag. valve - air feeding tube - air feeding tube 1
- automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil) - cyclone CCP 150/200, fan CVX 180
EKO-CKS P 550
149 - 499
EKO-CKS P UNIT 499
EKO-CKS P 600
168 - 560
EKO-CKS P UNIT 560
Cm Pelet-set 600: - pellet burner CPPL-600 inv (with automatic cleaning) - 2 pcs of expan. vessel 23 lit. - air compressor - boiler control - pellet screw conveyor CPPT-600
- 2 elektromag. ventila - air feeding tube - air feeding tube 1 - cyclone, fan CVX200
Cm Pelet-set 600: - pellet burner CPPL-600 inv (with automatic cleaning) - 2 pcs of expan. vessel 23 lit. - air compressor - boiler control - pellet screw conveyor CPPT-600
- 2 pcs of electromag.valve - air feeding tube - air feeding tube 1 - cyclone, fan CVX200
Other additional equipment (all outputs):
- automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil) - cyclone CCP 250/300, fan CVX 180 - automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil) - cyclone CCP 380, fan CVX 200 - automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil) - cyclone CCP 500, fan CVX 200
- automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil)
- safety elements set of min/max pressure, cascade manager CMNET, communication module CM-GSM, alarm module CAL, CM2K-B module for steering 2 heating circuits using outdoor temperature (max. 4x CM2K), supply transporters from other storages, pellet silos
Contact phone: +371 28818088, +371 29149923 E-mail: info@centrometal.lv Homepage: www.centrometal.lv
Wood pellet firing boilers EKO-CKS P UNIT BASIC DIMENSIONS Wood pellet firing boilers EKO-CKS P UNIT BASIC DIMENSIONS
Wood pellet firing boilers EKO-CKS P UNIT (140–560 kW)
EKO-CKS P UNIT hot water central heating boiler is designed for burning wood pellets. It consists of EKO-CKS P boiler body in welded steel design and equipment for combustion of wood pellets: Cm Pelet-set 200-600 kW. It is necessary to upgrade the EKO-CKS P UNIT boiler with a pellet tank (e.g. CentroPelet box), and EKO-CKS P UNIT 560 boiler’s standard delivery includes cyclone and fan. Standard version is equipped with a pellet burner prearranged for auto- matic air-cleaning of the grate while the boiler can be addi- tionally equipped automatic ash removal set and air-cleaning of flue passages in the boiler. Digital control manages the operations of the burner (boiler), pellet transporter and additional equipment and all mentioned parts compose a functional unit.
PRODUCT CHARACTERISTICS
SUITABLE FOR THE ENVIRONMENT Low emission of harmful compounds in the flue gases.
TOUCH SCREEN Multifunctional digital control with colour touch screen display.
EXTENSIONS Additional equipment: air-cleaning of flue pas- sages, ash removal, cyclone with fan, CM2K, CM-GSM, PC, tablet or mobile phone monitoring.
AUTOMATIC CLEANING Pellet burner prearranged for automatic air- cleaning of the grate.
 Wood pellet firing boilers EKO-CKS P UNIT PRODUCT CHARACTERISTICS Wood pellet firing boilers EKO-CKS P UNIT PRODUCT CHARACTERISTICS
Class 5 boiler. Steel hot water boilers with a pellet burner with nominal heat output: 140, 180, 230, 280, 320, 430, 499, 560 kW Boiler must be connected to accumulation tank (min. 10 l/kW) or hydraulic separator. Multifunctional digital control with colour touch screen display. Additional equipment: air-cleaning of flue passages, ash removal, cyclone with fan, CM2K, CAL, CM-GSM, system for monitoring the boiler operation via PC, tablet or mobile phone. They are meant to be installed in open or closed heating systems. It is possible to order a boiler with a lambda probe, EKO- CKS P-L Unit. The boiler is manufactured in accordance with the stan- dards EN 303-5:2012 as well as ISO 9001 and ISO 14001.
BASIC DIMENSIONS:
3
1 2 EKO-CKS P Unit 140/180 EKO-CKS P Unit 140-430 - with cyclone and fan (additional equipment) EKO-CKS P Unit 499-560 - with cyclone and fan (standard delivery)
EKO-CKS P Unit 230-430
EKO-CKS P Unit 140-320 - expansion vessel 50 lit. - 1 kom, electromagnetic valve - 1 kom, air supply pipe - 1 kom EKO-CKS P Unit 430-560 - expansion vessel 23 lit. - 2 kom, electromagnetic valve - 2 kom, air supply pipe - 2 kom
4
3
2
1
11
8
7
6
5
1 2 1 3 14
Boiler EKO-CKS P 140-560 Burner CPPL 200-600 Electrical distribution box Control unit Pellet transporter CPPT 200-600 Expansion vessel
Compressor Electromagnetic valve Air feeding tube Air feeding tube 1 Pellet tank
Automatic ash removal (additional equipment) Cyclone CCP Fan 15 Flue gas chamber / flue gas chamber C/V (for cyclone and fan)
9 10
4 4 4 4 4
3 3
3
3a
Automatic boiler cleaning (additional equipment)
EKO-CKS P UNIT
140
Depth (A) Height(B) Width (C) Depth (D) Visina (E) Connections inlet/outlet
(mm) (mm) (mm) (mm) (mm) (R)/DN
180 230 280 320 430 560
2620 2105 3300 3265 2210 2"
1 3 3
3020 2105 3300 3650 2210 2"
1 3 3
3020 2105 3300 3650 2210 DN80
2 3 3
3330 2300 3345 3985 2580 DN80
2 3 3
3330 2400 3420 4160 2725 DN80
2 3 3
4225 2565 3900 4690 2895 DN100
2 3 3
- - 360 0 4775 520 0 5200 287 0 3230 DN100
499 - -
DN100
BASIC DELIVERY:
Boiler
Output range (kW)
EKO-CKS P 500
129 - 430
EKO-CKS P 380
96 - 320
EKO-CKS P 250
69 - 230
EKO-CKS P 300
84 - 280
- pellet tank - boiler outlet protection with a motor operated 3-way mixing valve and boiler pump - accumulation tank (min 10 l/kW) or hydraulic crossover
EKO-CKS P 150
42 - 140
EKO-CKS P 200
54 - 180
Cm Pelet-set 200: - pellet burner CPPL-200 inv (with automatic cleaning) - expansion vessel 50 lit. - compressor
-
boiler control - pellet screw conveyor CPPT-200 - electromagnetic valve - air feeding tube
Cm Pelet-set 300: - pellet burner CPPL-300 inv (with automatic cleaning) - expansion vessel 50 lit. - air compressor
- boiler control - pellet screw conveyor CPPT-300/350 - electromagnetic valve - air feeding tube
Cm Pelet-set 350: - pellet burner CPPL-350 inv (with automatic cleaning) - expansion vessel 50 lit. - air compressor
- boiler control - pellet screw conveyor CPPT-300/350 - electromagnetic valve - air feeding tube
Cm Pelet-set
Obligatory additional equipment
Additional equipment
Basic delivery
EKO-CKS P UNIT 430
EKO-CKS P UNIT 320
EKO-CKS P UNIT 280
EKO-CKS P UNIT 230
EKO-CKS P UNIT 180
EKO-CKS P UNIT 140
Cm Pelet-set 600: - pelet burner CPPL-600 inv (with automatic cleaning) - 2 pcs of expan. vessel 23 lit. - air compressor - boiler control
- pellet screw conveyor CPPT-600 - 2 pcs of electromag. valve - air feeding tube - air feeding tube 1
- automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil) - cyclone CCP 150/200, fan CVX 180
EKO-CKS P 550
149 - 499
EKO-CKS P UNIT 499
EKO-CKS P 600
168 - 560
EKO-CKS P UNIT 560
Cm Pelet-set 600: - pellet burner CPPL-600 inv (with automatic cleaning) - 2 pcs of expan. vessel 23 lit. - air compressor - boiler control - pellet screw conveyor CPPT-600
- 2 elektromag. ventila - air feeding tube - air feeding tube 1 - cyclone, fan CVX200
Cm Pelet-set 600: - pellet burner CPPL-600 inv (with automatic cleaning) - 2 pcs of expan. vessel 23 lit. - air compressor - boiler control - pellet screw conveyor CPPT-600
- 2 pcs of electromag.valve - air feeding tube - air feeding tube 1 - cyclone, fan CVX200
Other additional equipment (all outputs):
- automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil) - cyclone CCP 250/300, fan CVX 180 - automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil) - cyclone CCP 380, fan CVX 200 - automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil) - cyclone CCP 500, fan CVX 200
- automatic pneumatic cleaning system of heat exchanger flue pipes - automatic ash removal system from burner (by coil) - automatic ash removal system from flue gas chamber (by coil)
- safety elements set of min/max pressure, cascade manager CMNET, communication module CM-GSM, alarm module CAL, CM2K-B module for steering 2 heating circuits using outdoor temperature (max. 4x CM2K), supply transporters from other storages, pellet silos
Wood pellet firing boilers EKO-CKS P UNIT BASIC DIMENSIONS Wood pellet firing boilers EKO-CKS P UNIT BASIC DIMENSIONS
Contact phone: +371 28818088, +371 29149923 E-mail: info@centrometal.lv
HEATING TECHNIQUE
Wood pellet firing boilers EKO-CKS P UNIT (140–560 kW)
Contact phone: +371 28818088, +371 29149923 E-mail: info@centrometal.lv Homepage: www.centrometal.lv
*The internal diameter and height of the chimney must be strictly in line with the boiler's nominal capacity. It must comply with all national regulatory documents and manufacturer's recommendations.