Nominal heat output
Ø(mm)
R
R
Filling/Draining
lue gases temperature
Max. operating temperature
R
25
Max. operating pressure
Boiler dimensions (A*C*B)
34
°C
°C
bar
mm
150/775
6/4"
6/4"
3/4"
130
90
2,5
1400*1330*585
160/800
6/4"
6/4"
3/4"
130
90
2,5
1370*1370*700
kW
45
180/1270
6/4"
6/4"
3/4"
130
90
2,5
1385*1565*700
*Chimney diameter/height
Boiler water inlet
Boiler water outlet
45
34
25
5 4 3 2
Boiler regulation; Boiler water inlet; Fan with electric motor; Flue gas exhaust; Boiler water outlet; Lever for cleaning flue gas tubes; Place for mounting the thermal valve; Side opening for cleaning the smoke chamber.
6
Max. wood piece length
Wood storage
mm
lit.
450-550
90
450-550
144
450-550
Boiler water content
lit.
115
Boiler mass
kg
519
606
677
130
176
150
Total boiler depth (H)
mm
775
800
1270
BioTec-L 25-45kW
1
7 8

Economical

Pyrolytic combustion makes it possible to use more than 85%, which saves considerably compared to classic wood boilers.

PRODUCT CHARACTERISTICS:

It is delivered pre-wired with the built-in boiler control unit to control the boiler. The built-in boiler control with the colour touch screen manages the boiler operation using the lambda probe, temperature sensor in the boiler combustion chamber, boiler sensor, motor for the management of primary and secondary air intake and changing the rpms of underpressure fan on the flue gases outlet from the boiler. Possible upgrade of the GSM alarm and the module for steering up to max.8 heating circuits via mixing valves to the outside or room temperature (additional equipment). In addition to the operation of the boiler, the boiler pump and the return flow (through the 3-way mixing valve and the return sensor), the control unit can manage the filling of the accumulation tank and heating of the domestic hot water tank (DHW sensor) (sensor + pump). Easy transportation and leveling by 4 adjustable legs of the boiler. The boiler is tested and certified according to EN 303-5: 2012 and meets Class 5. It is manufactured in accordance with ISO 9001 and ISO 14001 standard.

BASIC DIMENSIONS:

Obligatory additional equipment:

– accumulation tank for heating system (CAS (minimum 30 lit/kw boiler power)), 3-way thermostat valve, like ESBE LTC 141; (closed heating system) – thermal safety valve, safety-airvent group (2,5 bar) and expansion vessel; (open heating system ) – open expansion vessel.
HEATING TECHNIQUE
BioTec-C steel hot water boilers (with nominal heat output of 25 to 45 kW) are designed for wood log fuel firing for the heating of small and middle sized premises. The wood gasification principle enables a complete fuel burning. Logs up to 550 mm long can be inserted into the large combustion chamber. The burning period for a single fill of logs is at least 4 hours at the rated output and can be extended to a whole day if the need for heating is less. The boiler can keep the glow even 8 hours, which means that in this period it is not necessary to fire up the boiler in order to keep the heating process. Boiler operation is managed with inbuilt boiler control unit using the boiler temperature sensor and changing the rpm’s of underpressure fan on flue gases outlet from boiler. Boiler is connected to the central heating system through a 3-way thermostat valve accumulation (buffer) tank (like CAS, CAS B, CAS S, CAS BS). The boiler is tested and certified according to the European standard EN 303- 5:2012 and meets class 5. It is manufactured in compliance with ISO 9001/2008 and ISO 14001/2004 standard and meet the requirements for ECO design (commission (EU) 2015/1189).

WiFi READY

Digital boiler control supports Internet monitoring and control of boiler operation via the internet portal.

One charge per day

The duration of a single charge is at least 4 hours full power with the possibility of prolonging the entire day if the need for heating is reduced.

Large size wood

Large firebox allows wood to burn up to half a meter long.
Boiler Class 5. Meet the requirements for ECO design (COMMISSION (EU) 2015/1189). Hot water boiler for central heating systems is engineered for wood log firing of the moisture content under 25% (min 1 year long air dried wood). The wood gasification principle enables total burning of the fuel, reducing the cleaning of the boiler to minimum (depends on wood quality and nominal boiler load). The design and construction, including the wood gasification principle of complete burning assures high efficiency and makes the boiler extremely economical. It is environmentally friendly because of extremely low concentration of harmful components in flue gases. Three doors and the combustion chamber enable loading with large logs as well as very simple cleaning and maintenance. It is engineered for installation in open or closed central heating systems only through accumulation tanks (CAS), volume min. 50l/kW and a 3-way thermal valve at 60°C.

DELIVERY, ADDITIONAL EQUIPMENT:

Delivery: >Boiler with cas- ing,wired, with 4 ad- ditional sensors, external tempera- ture sensor, room corrector and clean- ing accessories (2 x scraper, brush, cleaning acces- sories holder).
Obligatory: Connection to CAS accumulation tank: > CAS accumulation tank, 3- way thermostatic valve LTC, VTC…. (60°C); or 3-way mixing valve with a motor actuator Closed heating system > thermal safety valve, safety-air vent group (2.5 bar) and expansion vessel; Open heating system > open expansion vessel
GSM alarm module for mo- bile network // CAL > notification of the boiler sta- tus through the mobile net- work text message or call (errors, warning..) > request for the boiler status phase of work, boiler tempera- ture, through an SMS mes- sage in the selected language CAL set alarm (speaker / light) > module for error notification by sound or light signal or warning about the boiler operation.
CM2K-B module for steer- ing 2 heating circuits// CSK > allows steering of up to 2 heating circuits to the out- side temp. (up to 2 mixing valves and up to 2 heating pumps. > possible connection to 4 CM2K-B modules (up to 8 heating circuits). > possible connection to 2 CSK room correctors per module. CSK > room corrector
English Deutsch Magyar v2.22 xxkW Italiano Français Portugues Čeština Srpski Slovenski Hrvatski Nederlands Espanol English Deutsch Magyar v2.22 xxkW Italiano Français Portugues Čeština Srpski Slovenski Hrvatski Nederlands Espanol
Connection to the system with one direct heating circle and DHW preparation: > CAS accumulation tank, 3-way ther- mostatic valve LTC, VTC…. (60°C); > 3-way mixing valve with a motor actu- ator DHW tank (TB, STEB) Closed heating system > thermal safety valve, safety-air vent group (2.5 bar) and expansion vessel; Open heating system > open expansion vessel
T T T T English Deutsch Magyar v2.22 xxkW Italiano Français Portugues Čeština Srpski Slovenski Hrvatski Nederlands Espanol
*The internal diameter and height of the chimney must be strictly in line with the boiler's nominal capacity. It must comply with all national regulatory documents and manufacturer's recommendations.
Contact phone: +371 28818088, +371 29149923 E-mail: info@centrometal.lv Homepage: www.centrometal.lv
BOILER CLASS  DESIGN

Wood firing boilers BioTec-L (25/35/45kW)

Nominal heat output
Ø(mm)
R
R
Filling/Draining
lue gases temperature
Max. operating temperature
R
25
Max. operating pressure
Boiler dimensions (A*C*B)
34
°C
°C
bar
mm
150/775
6/4"
6/4"
3/4"
130
90
2,5
1400*1330*585
160/800
6/4"
6/4"
3/4"
130
90
2,5
1370*1370*700
kW
45
180/1270
6/4"
6/4"
3/4"
130
90
2,5
1385*1565*700
*Chimney diameter/height
Boiler water inlet
Boiler water outlet
45
34
25
5 4 3 2
Boiler regulation; Boiler water inlet; Fan with electric motor; Flue gas exhaust; Boiler water outlet; Lever for cleaning flue gas tubes; Place for mounting the thermal valve; Side opening for cleaning the smoke chamber.
6
Max. wood piece length
Wood storage
mm
lit.
450-550
90
450-550
144
450-550
Boiler water content
lit.
115
Boiler mass
kg
519
606
677
130
176
150
Total boiler depth (H)
mm
775
800
1270
BioTec-L 25-45kW
1 7 8
Economical Pyrolytic combustion makes it possible to use more than 85%, which saves considerably compared to classic wood boilers.
PRODUCT CHARACTERISTICS
It is delivered pre-wired with the built-in boiler control unit to control the boiler. The built-in boiler control with the colour touch screen manages the boiler operation using the lambda probe, temperature sensor in the boiler combustion chamber, boiler sensor, motor for the management of primary and secondary air intake and changing the rpms of underpressure fan on the flue gases outlet from the boiler. Possible upgrade of the GSM alarm and the module for steering up to max.8 heating circuits via mixing valves to the outside or room temperature (additional equipment). In addition to the operation of the boiler, the boiler pump and the return flow (through the 3-way mixing valve and the return sensor), the control unit can manage the filling of the accumulation tank and heating of the domestic hot water tank (DHW sensor) (sensor + pump). Easy transportation and leveling by 4 adjustable legs of the boiler. The boiler is tested and certified according to EN 303-5: 2012 and meets Class 5. It is manufactured in accordance with ISO 9001 and ISO 14001 standard.
BASIC DIMENSIONS:
Obligatory additional equipment:
– accumulation tank for heating system (CAS (minimum 30 lit/kw boiler power)), 3-way thermostat valve, like ESBE LTC 141; (closed heating system) – thermal safety valve, safety-airvent group (2,5 bar) and expansion vessel; (open heating system ) – open expansion vessel.

Wood firing boilers BioTec-L

(25/35/45kW)

BioTec-C steel hot water boilers (with nominal heat output of 25 to 45 kW) are designed for wood log fuel firing for the heating of small and middle sized premises. The wood gasification principle enables a complete fuel burning. Logs up to 550 mm long can be inserted into the large combustion chamber. The burning period for a single fill of logs is at least 4 hours at the rated output and can be extended to a whole day if the need for heating is less. The boiler can keep the glow even 8 hours, which means that in this period it is not necessary to fire up the boiler in order to keep the heating process. Boiler operation is managed with inbuilt boiler control unit using the boiler temperature sensor and changing the rpm’s of underpressure fan on flue gases outlet from boiler. Boiler is connected to the central heating system through a 3-way thermostat valve accumulation (buffer) tank (like CAS, CAS B, CAS S, CAS BS). The boiler is tested and certified according to the European standard EN 303-5:2012 and meets class 5. It is manufactured in compliance with ISO 9001/2008 and ISO 14001/2004 standard and meet the requirements for ECO design (commission (EU) 2015/1189).
WiFi READY Digital boiler control supports Internet monitoring and control of boiler operation via the internet portal.
One charge per day The duration of a single charge is at least 4 hours full power with the possibility of prolonging the entire day if the need for heating is reduced.
Large size wood Large firebox allows wood to burn up to half a meter long.
Boiler Class 5. Meet the requirements for ECO design (COMMISSION (EU) 2015/1189). Hot water boiler for central heating systems is engineered for wood log firing of the moisture content under 25% (min 1 year long air dried wood). The wood gasification principle enables total burning of the fuel, reducing the cleaning of the boiler to minimum (depends on wood quality and nominal boiler load). The design and construction, including the wood gasification principle of complete burning assures high efficiency and makes the boiler extremely economical. It is environmentally friendly because of extremely low concentration of harmful components in flue gases. Three doors and the combustion chamber enable loading with large logs as well as very simple cleaning and maintenance. It is engineered for installation in open or closed central heating systems only through accumulation tanks (CAS), volume min. 50l/kW and a 3-way thermal valve at 60°C.
DELIVERY, ADDITIONAL EQUIPMENT:
Delivery: >Boiler with casing,wired, with 4 additional sen- sors, external temperature sensor, room cor- rector and cleaning accessories (2 x scraper, brush, cleaning accessories holder).
Obligatory: Connection to CAS ac- cumulation tank: > CAS accumulation tank, 3way ther- mostatic valve LTC, VTC…. (60°C); or 3-way mixing valve with a motor actuator Closed heating system > thermal safety valve, safety-air vent group (2.5 bar) and ex- pansion vessel; Open heating system > open expansion vessel
GSM alarm module for mobile net- work // CAL > notification of the boiler status through the mobile network text mes- sage or call (errors, warning..) > request for the boiler status phase of work, boiler temperature, through an SMS message in the selected language CAL set alarm (speaker / light) > module for error notification by sound or light signal or warning about the boiler operation.
CM2K-B module for steering 2 heating circuits// CSK > allows steering of up to 2 heating circuits to the outside temp. (up to 2 mixing valves and up to 2 heating pumps. > possible connection to 4 CM2K-B modules (up to 8 heating circuits). > possible connection to 2 CSK room correctors per module. CSK > room corrector
Connection to the system with one direct heating circle and DHW preparation: > CAS accumulation tank, 3-way thermostatic valve LTC, VTC…. (60°C); > 3-way mixing valve with a motor actuator DHW tank (TB, STEB) Closed heating system > thermal safety valve, safety-air vent group (2.5 bar) and expansion vessel; Open heating system > open expansion vessel
BOILER CLASS  DESIGN
Contact phone: +371 28818088, +371 29149923 E-mail: info@centrometal.lv
HEATING TECHNIQUE
Contact phone: +371 28818088, +371 29149923 E-mail: info@centrometal.lv Homepage: www.centrometal.lv
*The internal diameter and height of the chimney must be strictly in line with the boiler's nominal capacity. It must comply with all national regulatory documents and manufacturer's recommendations.